Easy UPS 3S 40kVA 400V 3:3 UPS 10 min

2 in stock (can be backordered)

n

Easy UPS 3S 40 kVA 400 V 3:3 UPS with internal batteries – 10 minutes runtime

n

n

n

n

n

n

    • n

    • n

      High-efficiency 3-phase UPS with internal batteries providing a runtime of 10 minutes. The UPS features advanced product features, competitive specifications, and …

      n

n

    • n

      Includes: Dust filter, Installation guide

      n

n

n

nnnnnnnnnnnnnnnnnnnnnnnnnnnn

General
provided equipment n

Dust filter
nInstallation guide
Number of power module free slots n

0
Number of power module filled slots n

0
redundant n

No
UPS size n

WS

n

nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn

Physical
colour n

White
depth n

96.9 cm
height n

140 cm
mounting preference n

No preference
net weight n

590 kg
mounting mode n

Not rack-mountable
two post mountable n

0
USB compatible n

No
width n

50 cm

n

nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn

Input
Network frequency n

45…65 Hz
input voltage limits n

304…477 V
inputvolt_other n

380 V
n415 V
maximum input current n

73 A
input harmonic distortion n

Less than 3 % for full load
input voltage n

400 V 3 phases
load power factor n

0.9 leading to 0.9 lagging
cos phi n

0.99

n

nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn

Output
rated power in W n

40000 W
Maximum configurable power in W n

40000 W
harmonic distortion n

Less than 3 %
output frequency n

50 Hz sync to mains
n60 Hz sync to mains
outputvolt_other n

380 V
n415 V
UPS type n

Double conversion online
output voltage tolerance n

+/- 1.5 %
output harmonic distortion n

< 3% linear load
curve equation n

Efficiency
curve fixed loss n

0.0042
curve load maximum n

100 %
curve load minimum n

1 %
curve proportional loss n

0.0258
curve square loss n

0.0208
curve X-axis maximum n

100 %
curve test cond ID n

Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with 400V 50Hz input and 400V 50Hz balanced resistive load (PF = 1.0) Output.
curve X-axis minimum n

0 %
curve X-axis title n

Load
curve X-axis units n

Percentage
curve Y-axis maximum n

100 %
curve Y-axis minimum n

50 %
curve Y-axis title n

Efficiency
curve Y-axis units n

Percentage
graph display n

1
output voltage n

400 V 3 phases
Maximum configurable power in VA n

40000 VA
rated power in VA n

40000 VA

Shop By Department

Easy UPS 3S 40kVA 400V 3:3 UPS 10 min